Vent Axia Sentinel Kinetic BH Heat recovery unit, whole hous
High efficiency, whole house heat recovery unit, SAP-Q eligible. Equipped With Summer Bypass and Integral Built-In Humidistat.
Delivered without the wall controller, if you like to use a wired wall controller, please add this to your order.
Features
- Recognised in SAP-Q database
- Ultra quiet
- Lightweight for easier installation
- Horizontal duct option for space-saving installations
- Fits within a 290mm deep kitchen cupboard
- Integrated digital controller for simple and accurate commissioning
- Plug and play controls; Humidistat, Ventwise, Wireless Remote
- BMS connectivity
- LS inputs (Light Switch)
- SEC Class A
- Horizontal duct options
Easy Installation
The Sentinel Kinetic models can be mounted vertically in a roof space, hallway cupboard or kitchen or within a kitchen cupboard. When mounted in an unheated area ducting and MVHR unit should be insulated. Ducting can be attached to the unit horizontally, vertically or both. Minimum internal depth of kitchen cupboard: V, B & BH models 290mm.
Left (L) or right (R) hand installation.
The unit is supplied with duct spigots to outside on the right hand side. These can be reversed on site by simply removing the control panel, rotating the unit 180 degrees and re-attaching the control panel.
Spigot Options
The combination of spigot options allows installation in confined locations. If vertical and horizontal connection is required on the same outlet/inlet, additional spigots can be supplied. The condensate drain can be taken out through the back, side or bottom of the unit. Using the fittings supplied, the final condensate connection is made outside the unit and can be completed after installation.
Integral Humidity Sensor (BH Models)
The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. The night time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature.
Read more why do we need to ventilate here.
Read more about the Heat Recovery units [MVHR unit] here.
Maximum Airflow Rate (l/s) | 65 |
---|---|
Maximum Airflow Rate (m3/h) | 234 |
Maximum Floor Area m2 | 150 |
Unit Connection | 125 |
Technical Information
Stock Reference | 443319 |
Product Type | Ventilation |
Product Range | Heat Recovery |
Impeller | Forward Curved |
Casing | ABS |
Speed | Variable |
Airstream Temperature | -20°C to 45°C |
dBA | 39 dBA @ 3m |
Warranty | Up to 5 years |
Electricial Information
Supply Voltage | 220-240V/1/50Hz |
Motor IP Rating | IP22 |
S.T.O.P. Protection | Yes |
Speed Controllable | In Built |
Sound Information at Duty Point
63 | 125 | 250 | 500 | 1k | 2k | 4k | 8k | Total | dBA@3m | |
Inlet | 66 | 63 | 60 | 56 | 51 | 44 | 36 | 32 | 69 | 37 |
Outlet |
70 | 75 | 73 | 66 | 63 | 59 | 53 | 50 | 78 | 49 |
Breakout |
59 | 55 | 56 | 55 | 56 | 53 | 47 | 41 | 64 | 39 |
Drawing & Dimensions
A 550 |
B 550 |
C 285 |
D 140 |
E 125 |
F 360 |
G 90 |
Weight 15 |